PHYSICAL CHARACTERISTICS : |
 |
|
| |
|
|
CONDUCTOR : |
| Number of Coax: |
1 |
| Total Number of Conductors: |
1 |
| Series Type: |
Series 11 |
| AWG: |
14 |
| Stranding: |
Solid |
| Conductor Diameter: |
.064 in. |
| Conductor Material: |
BCCS - Bare Copper Covered
Steel |
| |
|
|
INSULATION : |
| Insulation Material: |
Gas-injected FPE - Foam
Polyethylene |
| Insulation Diameter: |
.280 in. |
|
|
|
|
OUTER SHIELD : |
| Outer Shield Material
Trade Name: |
Duobond® II |
| Outer Shield Type: |
Tape/Braid |
| Outer Shield Material:
|
|
| Layer Number |
Trade Name |
Type |
Material |
% Coverage (%) |
| 1 |
Duobond® |
Tape |
Bonded Duofoil® |
100 |
| 2 |
|
Braid |
AL- Aluminum |
60 |
|
|
|
|
|
|
|
OUTER JACKET : |
| Outer Jacket Material: |
PVC - Polyvinyl
Chloride |
|
|
|
|
OVERALL NOMINAL DIAMETER : |
| Overall Nominal
Diameter: |
.400 in. |
|
MECHANICAL CHARACTERISTICS : |
 |
|
| Operating
Temperature Range: |
-40°C To
+80°C |
| Non-UL
Temperature Rating: |
80°C |
| Bulk Cable
Weight: |
54 lbs/1000
ft. |
| Max. Recommended
Pulling Tension: |
260 lbs. |
| Min. Bend Radius
(Install): |
4.5 in. |
|
APPLICABLE
SPECIFICATIONS AND AGENCY COMPLIANCE : |
 |
|
|
|
|
|
APPLICABLE STANDARDS : |
| NEC/(UL)
Specification: |
CM, CATV
|
| CEC/C(UL)
Specification: |
CM |
|
|
|
|
FLAME TEST : |
| UL Flame
Test: |
UL1581 Vertical Tray |
|
|
|
|
PLENUM/NON-PLENUM : |
|
Plenum (Y/N): |
Y
|
|
ELECTRICAL
CHARACTERISTICS : |
 |
|
|
Nom. Characteristic Impedance: |
75 Ω |
|
Nom. Inductance: |
.097 µH/ft |
|
Nominal Velocity of Propagation: |
83 % |
|
Nominal Delay: |
1.2 ns/ft |
|
Nom. Conductor DC Resistance @ 20
Deg. C: |
11.0 Ω/1000 ft |
|
Nominal Outer Shield DC Resistance @
20°C: |
4.1 Ω/1000 ft |
|
Minimum Structural Return Loss: |
|
|
Description |
Frequency (MHz) |
Start Frequency (MHz) |
Stop Frequency (MHz) |
Minimum Structural Return
Loss (dB) |
| |
|
5 |
1000 |
20 |
|
|
|
|
|
|
Description |
Frequency (MHz) |
Start Frequency (MHz) |
Stop Frequency (MHz) |
Max. Attenuation (dB/100 ft.) |
| |
5 |
|
|
0.38 |
| |
55 |
|
|
0.97 |
| |
211 |
|
|
1.81 |
| |
270 |
|
|
2.05 |
| |
300 |
|
|
2.15 |
| |
350 |
|
|
2.32 |
| |
400 |
|
|
2.47 |
| |
450 |
|
|
2.65 |
| |
550 |
|
|
2.94 |
| |
750 |
|
|
3.50 |
| |
870 |
|
|
3.84 |
| |
1000 |
|
|
4.23 |
|
|
|
|
Max. Operating Voltage - UL: |
600 V RMS |
|
NOTES : |
 |
|
|
Notes: |
Sweep tested 5 MHz to 1 GHz. |
|
PUT-UPS AND COLORS: |
 |
|
|
Item |
Description |
Put-Up (ft.) |
Ship Weight (lbs.) |
Jacket Color |
Notes |
|
1523A 0091000 |
#14 GIFHDLDPE SH PVC |
1000 |
69 |
WHITE |
C |
|
1523A 0101000 |
#14 GIFHDLDPE SH PVC |
1000 |
63 |
BLACK |
|
|
C = CRATE REEL PUT-UP. |
|
|
Revision Number: 1 Revision
Date: 02-24-2004 |
| |
| |
|
|
![]() |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
©
2003 Belden Wire & Cable Company |
| |
All Rights Reserved. |
|
Although Belden Electronics Division
("Belden") makes every reasonable effort
to ensure their accuracy at the time of
this publication, information and
specifications described herein are
subject to error or omission and to
change without notice, and the listing
of such information and specifications
does not ensure product availability. |
| |
Belden provides the information and
specifications herein on an "AS IS"
basis, with no representations or
warranties, whether express, statutory
or implied. In no event will Belden be
liable for any damages (including
consequential, indirect, incidental,
special, punitive, or exemplary damages)
whatsoever, even if Belden has been
advised of the possibility of such
damages, whether in an action under
contract, negligence or any other
theory, arising out of or in connection
with the use, or inability to use, the
information or specifications described
herein. |
|
All sales of Belden products are subject
to Belden's standard terms and
conditions of sale. |
|
|
|
|
|
|
|
|
|