Part Number: 9116    Coax  -  Broadband Coax CATV Cable         
For more information please call





 
DESCRIPTION:
18 AWG solid .040" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® II and a 60% aluminum braid shield, PVC jacket. 
PHYSICAL CHARACTERISTICS :
   
CONDUCTOR :
Number of Coax: 1
Total Number of Conductors: 1
Series Type: Series 6
AWG: 18
Stranding: Solid
Conductor Diameter: .040 in.
Conductor Material: BCCS - Bare Copper Covered Steel
   
INSULATION :
Insulation Material: Gas-injected FPE - Foam Polyethylene
Insulation Diameter: .180 in.
   
OUTER SHIELD :
Outer Shield Material Trade Name: Duobond® II
Outer Shield Type: Tape/Braid
Outer Shield Material:
Layer Number  Trade Name  Type  Material  % Coverage (%) 
 1  Bonded Duofoil®  Tape  Bonded Aluminum Foil-Polyester Tape-Aluminum Foil  100
 2    Braid  AL - Aluminum  60
 
Outer Shield %Coverage: 100 %
   
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
   
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .270 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -40°C To +80°C
Bulk Cable Weight: 30 lbs/1000 ft.
Max. Recommended Pulling Tension: 126 lbs.
Min. Bend Radius (Install): 3 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
   
APPLICABLE STANDARDS :
NEC/(UL) Specification: CATV, CM
CEC/C(UL) Specification: CM
   
FLAME TEST :
UL Flame Test: UL1581 Vertical Tray
   
PLENUM/NON-PLENUM :
Plenum (Y/N): N
Plenum Number: 9116P
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 75 +/-3 Ω
Nom. Inductance: .097 µH/ft
Nom. Capacitance Conductor to Shield: 16.2 pF/ft
Nominal Velocity of Propagation: 83 %
Nominal Delay: 1.2 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C: 28 Ω/1000 ft
Nominal Outer Shield DC Resistance @ 20°C: 9 Ω/1000 ft
Minimum Structural Return Loss:
Description  Frequency (MHz)  Start Frequency (MHz)  Stop Frequency (MHz)  Minimum Structural Return Loss (dB) 
     5  1000  20
 
Max. Attenuation:
Description  Frequency (MHz)  Start Frequency (MHz)  Stop Frequency (MHz)  Max. Attenuation (dB/100 ft.) 
   5      0.67
   55      1.60
   211      2.87
   270      3.24
   300      3.43
   350      3.72
   400      4.00
   450      4.26
   550      4.71
   750      5.59
   870      6.00
   1000      6.54
 
Max. Operating Voltage - UL: 350 V RMS
NOTES :
Notes: Sweep tested 5 MHz to 1 GHz.
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
 9116 0091000  #18 GIFHDLDPE SH PVC  1000  32  WHITE  
 9116 009500  #18 GIFHDLDPE SH PVC  500  17.5  WHITE  
 9116 009U1000  #18 GIFHDLDPE SH PVC  U1000  31  WHITE  
 9116 009U500  #18 GIFHDLDPE SH PVC  U500  15.5  WHITE  
 9116 0101000  #18 GIFHDLDPE SH PVC  1000  32  BLACK  C
 9116 010500  #18 GIFHDLDPE SH PVC  500  17.5  BLACK  
 9116 010S700  #18 GIFHDLDPE SH PVC  S700  18.9  BLACK  
 9116 010U1000  #18 GIFHDLDPE SH PVC  U1000  31  BLACK  
 9116 010U500  #18 GIFHDLDPE SH PVC  U500  15.5  BLACK  
 9116 290U1000  #18 GIFHDLDPE SH PVC  U1000  31  BEIGE, LIGHT  
 9116 Q5H1000  #18 GIFHDLDPE SH PVC  1000  32  WHITE, NEUTRAL  
 9116 Q5HU1000  #18 GIFHDLDPE SH PVC  U1000  31  WHITE, NEUTRAL  

C = CRATE REEL PUT-UP.



 

Revision Number: 1    Revision Date: 02-02-2004
 
 
       
 


 

© 2003 Belden Wire & Cable Company

  All Rights Reserved.

Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability.

  Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
5/3/04